Comparison of Passive Haemagglutination and Neutralization Tests to Demonstrate Genital Herpes Virus (HSV2) Antibodies in Pregnant Women
چکیده:   (4939 مشاهده)
Background and Aims: Herpes simplex virus (HSV) is responsible for several significant human viral diseases, with severity ranging from subclinical to fatal infection. Herpes simplex virus type 2 (HSV2) infections are more commonly seen in association with the genitalia and surrounding areas, and can be transmitted to newborns during childbirth. Generalized infections in newborns are also predominantly HSV2. Therefore, due to the increasing HSV2 infections especially subclinical in women, the need to diagnose herpes simplex virus infections has increased. Materials and Methods: In the present study, the passive haemagglutination (PHA) test was applied to determine the titer of Anti-HSV2 antibodies. Sheep red blood cells (SRBCs) were treated with tannic acid at concentration of 0.002% and sensitized with HSV2 that had been propagated in HeLa cells. The tannic acid treated and HSV2 sensitized SRBCs were added to U-shaped 96 wells microtiter plates which contained serial dilutions of patient’s sera. Furthermore, serum neutralization test (SNT) was applied as a gold standard to determine the specificity and sensitivity of PHA test. Results: The results of PHA were examined after one hour incubation at 37°C. The endpoint was the highest dilution of serum which gave positive agglutination and compaired with serum neutralization test (SNT as a gold standard to determine the specificity and sensitivity of PHA test. Peripheral blood samples were obtained from 100 pregnant women and evaluated by both SNT and PHA tests. The specificity and sensitivity of PHA test were 92.68%, and 100% respectively. The results indicated that PHA test was easy, rapid and inexpensive but also had acceptable sensitively and specificity. Conclusion: PHA test can be used to determine the level of Anti-HSV2 antibodies and the rate of infection in pregnant women which could be an indication of infection and the risk of transmitting herpes to the newborn.
متن کامل [PDF 309 kb]   (1166 دریافت)    
نوع مطالعه: پژوهشي | موضوع مقاله: عمومى
دریافت: 1393/8/16 | پذیرش: 1393/8/16 | انتشار: 1393/8/16
ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

CAPTCHA



XML   English Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Nejati M, Soleimanjahi H, Roostaee M, Pourhossein B. Comparison of Passive Haemagglutination and Neutralization Tests to Demonstrate Genital Herpes Virus (HSV2) Antibodies in Pregnant Women. Iran J Virol 2011; 5 (4) :1-5
URL: http://journal.isv.org.ir/article-1-77-fa.html

Comparison of Passive Haemagglutination and Neutralization Tests to Demonstrate Genital Herpes Virus (HSV2) Antibodies in Pregnant Women. مجله ویروس شناسی ایران. 1390; 5 (4) :1-5

URL: http://journal.isv.org.ir/article-1-77-fa.html



بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.
دوره 5، شماره 4 - ( 8-1390 ) برگشت به فهرست نسخه ها
Persian site map - English site map - Created in 0.05 seconds with 37 queries by YEKTAWEB 4645